Baseline Assurance Standard¶
ID | S108 |
|---|---|
Version | 1.0.5 |
Type | Overarching Standard |
Status | Effective |
Effective Date | |
Contracting Vehicle(s) |
- Introduction
- Requirements
- Business Continuity and Disaster Recovery
- Clinical Safety
- Commercial
- Data Migration
- Data Standards
- Hosting & Infrastructure
- NHS Cloud Hosting Standards & Guidance
- The Authority's Associated Cloud Guidance Links:
- Co-location and Provider Data Centre Hosting & Infrastructure Requirements
- Scope
- Information Governance
- Interoperability Standard
- Interoperability non-functional requirements
- Minimum non-functional requirements for interfaces built to the Authority's specifications
- Non-Functional Questions
- Service Management
- Testing
- Training
- Roadmap
Introduction¶
The Baseline Assurance Standard (BAS) provides a proportionate, risk-based assurance approach for Solutions; balancing safety against efficiency by combining a minimum set of essential Requirements from the DSIC Overarching Standards.
Completing the BAS is the first step to achieving full assurance with the Overarching Standards allowing Supplier Solutions to be published on the Buying Catalogue. Upon meeting this Standard, Solutions are required to meet any remaining Further Requirements in the Overarching Standards in the timeframe applicable to the Contracting Vehicle.
Solutions will be given a Solution Category; this will determine the level of assurance that is appropriate for the type of Solution. The Solution Category columns indicate which level of assurance is required for each Requirement. For more information on Solution Categories, see Solution Categories for Assurance in DSIC.
Requirements¶
Business Continuity and Disaster Recovery¶
Ensures that Suppliers Solutions are supported by robust business continuity plans and disaster recovery measures.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
| BC-DR-1 | Business Continuity Management System (BCMS) - methodology The Supplier’s organisation and the services provided will be underpinned by a robust Business Continuity Management System (BCMS). The Supplier must meet or exceed its recovery time objective, be fully accountable and responsible for its BCMS operational business continuity and IT Service Continuity Plans and supporting procedures for all services delivered to its Service Recipients. | MUST | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. The BCMS methodology, processes, standards and resources associated to the BCMS will utilise the relevant provisions of ISO/IEC 22301, ISO/IEC 27031, ISO/IEC 27001 and other good industry practice such as the Business Continuity Institute Good Practice Guidelines. | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. The BCMS methodology, processes, standards and resources associated to the BCMS will utilise the relevant provisions of ISO/IEC 22301, ISO/IEC 27031, ISO/IEC 27001 and other good industry practice such as the Business Continuity Institute Good Practice Guidelines. | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. The BCMS methodology, processes, standards and resources associated to the BCMS will utilise the relevant provisions of ISO/IEC 22301, ISO/IEC 27031, ISO/IEC 27001 and other good industry practice such as the Business Continuity Institute Good Practice Guidelines. |
| BC-DR-16 | Test and Exercise Programme - Business Continuity Test The Supplier will undertake a business continuity test at least annually in order to validate the effectiveness of its business continuity strategies. The Authority may wish to witness the test. See Business Continuity and Disaster Recovery Testing for guidance. | MUST | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. |
| BC-DR-16A | Test and Exercise Programme - IT Service Continuity The Supplier will undertake Disaster Recovery testing of the system at least annually. The testing must demonstrate that, in the event of an incident impacting availability, the system can be maintained and recovered within the Recovery Time Objective and that data can be restored within the Recovery Point Objective in the event of an incident. The Authority may wish to witness the test. If requested, the Supplier must comply and provide full access and visibility of the execution of the test, including access to documentation and the execution of procedures throughout the whole test and the resolution of any issues that occur during the Testing window. See Business Continuity and Disaster Recovery Testing for guidance. | MUST | Full Assessment Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. |
| BC-DR-20 | BCM & IT Service Continuity Management (ITSCM) Coverage The BCDR Plan must set out the method(s) of recovering or updating data collected, or which ought to have been collected, during a failure or disruption to ensure that there is no more than the accepted amount of data loss and to preserve data integrity. | MUST | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. | Self-certification with Supporting Evidence Supporting evidence could include:
Alternatively, instead of Self-certification, provide the BCMS methodology document detailing how the Requirement is met with supporting evidence as detailed above. |
Clinical Safety¶
Supports the management of clinical risk and Patient safety.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
| GP-08.4.3.01 | Compliance with Clinical Risk Management: Its Application in the Manufacture of Health IT Systems The Supplier to be compliant with the following Standard in respect of Clinical Safety: The submitted safety documents shall be fit for purpose to enable the deploying organisations to undertake an informed risk assessment in line with the requirements specified in the following Standard:
Note: The Clinical Safety Hazard Log must be well-structured, clear, and complete, showing the lifecycle of each identified hazard from detection through risk evaluation, mitigation, and monitoring. The log must enable easy tracking of updates with version control or timestamps and demonstrate alignment with the Clinical Safety Management System frameworks. Evidence must be provided in a format that facilitates straightforward review and assurance activities. | MUST | Full Assessment Supporting evidence to include:
NHS England Clinical Safety Group (CSG) will issue a Clinical Authority to Release (CATR) when the following are complete:
Where necessary this may include additional assurance activities, such as: targeted assessment of end‑to‑end clinical workflows, and/or clinical witnessing sessions to validate real‑world use, risk controls, and mitigations. | Full Assessment Supporting evidence to include:
NHS England Clinical Safety Group (CSG) will issue a Clinical Authority to Release (CATR) when the following are complete:
Where necessary this may include additional assurance activities, such as: targeted assessment of end‑to‑end clinical workflows, and/or clinical witnessing sessions to validate real‑world use, risk controls, and mitigations. | Full Assessment Supporting evidence to include:
NHS England Clinical Safety Group (CSG) will issue a Clinical Authority to Release (CATR) when the following are complete:
Where necessary this may include additional assurance activities, such as: targeted assessment of end‑to‑end clinical workflows, and/or clinical witnessing sessions to validate real‑world use, risk controls, and mitigations. |
| GP-MW-2.1-1 | MHRA Compliance The Supplier shall consider whether their Solution falls under the MD regulation using the relevant UK MDR 2002 guidance and declare whether the Solution is classed as a Medical Device within the CSCR. For information see the MHRA website. Note: This is only for information and completeness purposes and the Clinical Safety Group will not undertake any assessment against compliance with MHRA MD Standards. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
Commercial¶
This Standard underpins all commercial activity relating to the Catalogue. It does this by defining a number of rules governing the commercial relationship of relevant parties and by setting out standards of behaviour and principles of access to data and services charges.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
| C01 | MUST | Full Assessment Supporting evidence to include:
| Full Assessment Supporting evidence to include:
| Full Assessment Supporting evidence to include:
|
Data Migration¶
Supports the secure migration of Practice data between Solutions.
Applicable Contracting Vehicle(s) | ID | Requirement | Applies to | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|---|
Target and Source Solution Suppliers | |||||||
| DMI01 | Provide a Data Migration Approach document which details their approach to a Data Migration when acting both as Source and Target Solution Supplier. Note: This is a high level, generic document to be provided to the Authority as part of Standards Compliance and then to be tailored according to the needs of each Data Migration undertaken. | Target and Source | MUST | Full Assessment Supporting evidence to include:
Data Migration Approach document to include as a minimum:
| Self-certification with Supporting Evidence Supporting evidence to include:
Data Migration Approach document to include as a minimum:
| Self-certification with Supporting Evidence Supporting evidence to include:
Data Migration Approach document to include as a minimum:
|
| DMI02 | Provide a Documented Data Extract (DDE) that allows a Target Solution Supplier to understand and interpret the form and structure of the extracted data. This will include, but is not limited to:
Note: This is an overarching DDE to be provided to the Authority as part of Standards Compliance and then tailored according to the specifics of each Data Migration undertaken. | Target and Source | MUST | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| DMI27 | Perform a migration of data from a Source Solution Supplier (SSS) to a Target Solution Supplier (TSS) over the internet, conforming to the Cross Functional Requirements outlined within the DMS Data Transfer - Cross Functional Requirements Document. Suppliers are to agree their own process and solution for transferring extracts, so long as the outcome is in line with the requirements set out within the DMS Data Transfer Cross Functional Requirements Document and the overall Data Migration Standard. Where agreement cannot be found, the fall back process described here is to be used. | Target and Source | MUST | Self-certification with Supporting Evidence Self-certification description to include:
If the Source Solution Supplier uses multiple Data Transfer Mechanisms to support multiple Target Solution Suppliers, self-certification description to include:
| Self-certification Self-certification description to include:
If the Source Solution Supplier uses multiple Data Transfer Mechanisms to support multiple Target Solution Suppliers, self-certification description to include:
| Self-certification Self-certification description to include:
If the Source Solution Supplier uses multiple Data Transfer Mechanisms to support multiple Target Solution Suppliers, self-certification description to include:
|
Source Solution Suppliers only | |||||||
| DMI05 | Support the Service Recipient with improving the data quality in the Source Solution up to the minimum standard agreed by all parties in preparation for the data extracts. See documents available here for guidance regarding data cleansing and preparation of data for a migration. | Source | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| DMI06 | Provide a minimum of two separate data extracts to the Target Solution Supplier and/or the Service Recipient to include:
NB. The provision of additional extracts may be required to facilitate the data transformation and data migration activities as detailed in the Data Migration Process set out in the Catalogue Solution Migration Process Ancillary Document. | Source | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| DMI07 | All data extracts will:
| Source | MUST | Self-certification Self-certification description to include:
| Self-certification Self-certification description to include:
| Self-certification Self-certification description to include:
|
| DMI26 | All data extracts to contain the full set of audit trails where applicable to the individual migration event. | Source | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| DMI08 | Provide a document and reports detailing any irregularities regarding the way in which data has been entered into the Source Solution (i.e. variances on the DDE), including reference to any dependencies on other Solutions and Suppliers. | Source | MUST | Self-certification | Self-certification | Self-certification |
| DMI09 | Provide access to the Source Solution, including data and audit trails in human readable format, and support services for the duration of the agreed Run-Off period as a minimum, according to the terms of the applicable contracts and agreements for that Data Migration and/or at the request of the Service Recipient. Note: Reference access to the Source Solution may be required for some time after completion of the Data Migration activities. | Source | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
Target Solution Suppliers only | |||||||
| DMI11 | Undertake the data transformation and mapping of data from the extracts provided by the Source Solution Supplier to a format which can be loaded into the Target Solution. | Target | MUST | Self-certification | Self-certification | Self-certification |
| DMI12 | Undertake the data transformation and mapping of data using the latest version of the approved mapping tables published by UK Terminology Centre (UKTC). | Target | MUST | Self-certification | Self-certification | Self-certification |
| DMI13 | Where mapping cannot be completed using the UKTC mapping tables, provide and describe the mapping tables used during the data transformation activities. | Target | SHOULD | Self-certification | Self-certification | Self-certification |
| DMI14 | Provide tables detailing any specific mappings between the Source Solution data and the Target Solution. | Target | MUST | Self-certification | Self-certification | Self-certification |
| DMI15 | Facilitate as many iterations of the data transformation and mapping as required to address all errors, omissions, and irregularities to the satisfaction of the Service Recipient. Note: If greater than five iterations of the data extract and transformation process are required, this will need to be reported to the Authority. | Target | MUST | Self-certification | Self-certification | Self-certification |
| DMI17 | Provide the Service Recipient with the transformed data and a trial environment to enable the validation of the integrity, accuracy and completeness of the data. | Target | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| DMI18 | Maintain an Issues Log of all issues encountered during the data transformation, including how and when each was resolved. | Target | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| DMI19 | Undertake any corrective action necessary to address issues raised regarding the data transformation and document this in the Issues Log. | Target | MUST | Self-certification | Self-certification | Self-certification |
| DMI20 | Provide comprehensive aggregated reports to enable the Service Recipient to verify the integrity, accuracy and completeness of the transformed data. As a minimum these will include:
| Target | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| DMI21 | Reports will be available at all times from the live and/or trial Environments (as applicable) from the moment the corresponding environment is made available. | Target | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| DMI22 | Reports to be refreshed every time data is re-loaded. | Target | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| DMI23 | Load the transformed data into the Target Solution once approved by the Service Recipient. | Target | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| DMI24 | Ensure staff, facilities, tools, training and support services, including floor-walking staff, are in place to support the Service Recipient in use of the Target Solution and to ensure that any obligations and responsibilities can continue to be met effectively. | Target | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
Data Standards¶
Defines detailed technical standards for the storage, management and organisation of data and specifies standardised reference data, terminology and codes.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
Data & Information Standards | ||||||
| DS01 | NHS Data Dictionary Standards Adhere to NHS Data Dictionary and Manual Standards for field lengths and formats, and codes for lists. | MUST | Self-certification Self-certification description to include:
| Self-certification Self-certification description to include:
| Self-certification Self-certification description to include:
|
| SCT11 | NHS Number ISB The Supplier will adhere to the NHS Number Standard (ISB 0149). | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
Reference Data | ||||||
| SCT3.7 | Coding & Terminology If your Solution contains Clinical Information it must be coded against the UK Edition SNOMED CT. For further information, see SNOMED CT. | MUST | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| SCT3.1 | Coding & Terminology - Up to date edition The most up to date UK Edition of SNOMED CT will be implemented within the Solution. See TRUD for the latest edition. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| GP-REF-2.1.2 | Terminology Mapping Where a Solution contains legacy primary clinical coded data (either Read V2 or CTV3) the Solution to map to SNOMED CT using the mapping tables published on TRUD; the maps to be used irrespective of the ‘IsAssured’ flag (indicator within the mapping tables). Suppliers are required to do this once when migrating from legacy coded data to SNOMED CT but will continue to be able use the mapping tables if they so choose. The Solution to allow users to identify coded data mapped using an unassured map. For all other purposes, the ‘IsAssured’ flag to be considered/interpreted and used as specified by the relevant requirements e.g. GP2GP. Where not specified the map to be used irrespective of the flag status. Suppliers can use alternative maps as agreed with the Authority for the codes highlighted for special attention (e.g. for codes with values using the 'Alternate Maps' file) - see NHS Data Migration on TRUD. | MUST | Self-certification | Self-certification | Self-certification |
| GP-REF-2.1.3 | Amendments to the Authority's Mapping Tables Where a Solution contains legacy primary clinical coded data (either Read V2, or CTV3) to address errors or agreed changes to maps in the national mapping tables, the Solution to ensure it is possible to re-map data already mapped to SNOMED CT via an updated mapping table. | MUST | Self-certification | Self-certification | Self-certification |
| GP-REF-2.1.8 | Code Mapping/Migration Audit Trail The Solution to retain in full, an audit of all past and present code mappings/data migration activity, and for this to be accessible with the correct permissions via the Solution User Interface. See Information Governance Standard for audit requirements. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| GP-03.1-01 | Primary Source of organisations and individuals reference data Use ODS as the primary source of reference data for organisations and individuals (ODS is the legal source for organisational information). For further information see ODS. Also see TRUD link for ODS. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification | Self-certification |
| SCT8 | Automatic identification and data capture (AIDC) The Supplier will ensure that where Automatic identification and data capture (AIDC) is used that the ISB Standards are followed. For Standards on identification see: | MUST | Self-certification with Supporting Evidence Self-certification description to include:
Supporting evidence to include:
| Self-certification Self-certification description to include:
| Self-certification Self-certification description to include:
|
| MR2.4.01 | Subscription to Notification Services The Supplier will subscribe to the following TRUD services:
Subscription to these services will ensure that the Supplier is notified (via email) on the day that any new release is made available to download from TRUD. The notification date will be regarded as the date of release. | MUST | Self-certification | Self-certification | Self-certification |
| SCT6 | NHS Dictionary of Medicines and Devices (dm+d) The Supplier will ensure that all Solutions support the NHS Dictionary of Medicines and Devices (dm+d) Standard. dm+d is a dictionary containing unique identifiers (codes) and associated textual descriptions for representing medicines and medical devices in information systems and electronic communications. This is of particular importance to the supporting of prescribing items. See Dictionary of medicines and devices (dm+d). | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| DS03 | Reference Data Updates The Supplier will deploy updates to any reference data within 8 weeks of its release. Release notifications are issued by TRUD. | MUST | Self-certification | Self-certification | Self-certification |
| GP-03.2-09 | Prevent amendment of reference data Prevent Users from amending the source/underlying data from any nationally provided Reference Data. | MUST | Self-certification | Self-certification | Self-certification |
Hosting & Infrastructure¶
Supports best practices for infrastructure and hosting of systems. For example, ensuring that systems are cost effective, secure, reliable, resilient, safe, manageable and energy efficient.
NHS Cloud Hosting Standards & Guidance¶
The following is a summary of the "NHS and social care data: off-shoring and the use of public cloud services" gathered from cloud guidance information published by the Authority. It makes clear what evidence is to be sought from a Supplier, where it is deemed necessary to assure compliance with the 4 step process.
Some key points of note:
- All decisions in relation to the security of data are the responsibility of the data controller(s). Also, in many cases organisations will have a SIRO responsible for data and cyber security
- Where a professional body exists, there is certainly merit in seeking their approval for the migration of data to cloud, but ultimately the data controller remains the key approver
- Data Controllers need to understand the risks of moving to cloud, and any impact
- Data controllers must take into account the standard CIA triad (Confidentiality, Integrity, Availability), and also other relevant factors, including, but not limited to, cost, security, resilience, capability and funding
The Authority's Associated Cloud Guidance Links:¶
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
Cloud Hosting Standards | ||||||
| CH1.0 | Understand the data All data managed by NHS and social care organisations should be treated as OFFICIAL or OFFICIAL-SENSITIVE data, in line with the Government Security Classification Policy. The Authority has further elaborated the very broad classifications. The Health and Social Care Cloud Risk Model is more granular than the Government Security Classification Policy. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| CH2.0 | Assess the Risks The Authority's Health and Social Care data risk framework and associated data risk model are both used to establish the risk level of the data. Typically Personally Identifiable Data (PID) would be Level 5. Please refer to the link NHS and social care data: off-shoring and the use of public cloud services for latest versions of Cloud risk framework and Health and social care data risk model. | MUST | Self-certification with Supporting Evidence Self-certification description to include:
Supporting evidence to include:
| Self-certification with Supporting Evidence Self-certification description to include:
Supporting evidence to include:
| Self-certification with Supporting Evidence Self-certification description to include:
Supporting evidence to include:
|
| CH3.0 | Implement the appropriate controls Care organisations, such as GPs, retain the data controller responsibilities and they are therefore ultimately responsible for ensuring that proportionate controls are put in place to mitigate all risks. The data controllers may rightly request to see these controls (proposed by the Supplier) before considering any migration to cloud. | MUST | Full Assessment Self-certification description to include:
Supporting evidence to include:
Note: To submit this evidence, download and complete the Cloud Good Practice Guide template for the data classification level identified in CH2.0. | Self-certification with Supporting Evidence Self-certification description to include:
Supporting evidence to include:
Note: To submit this evidence, download and complete the Cloud Good Practice Guide template for the data classification level identified in CH2.0. | Self-certification with Supporting Evidence Self-certification description to include:
Supporting evidence to include:
Note: To submit this evidence, download and complete the Cloud Good Practice Guide template for the data classification level identified in CH2.0. |
| CH4.0 | Monitoring the Implementation All cloud providers take on data processor responsibilities, with Care organisations (e.g. GP practices) retaining the data controller responsibilities, and they must ensure the selected cloud provider remains fit for purpose. | MUST | Self-certification | Self-certification | Self-certification |
Co-location and Provider Data Centre Hosting & Infrastructure Requirements¶
Scope¶
The scope of this document covers the infrastructure requirements a Supplier must meet when providing services where a Supplier has co located their service & infrastructure within a data centre providers facilities OR where the Supplier is using their own facilities. The requirements will cover a number of aspects including but not limited to:
- Provision of power and cooling
- Networking and IT Infrastructure
- Management of the Data Centre
- Physical presence of the data centre and the IT build processes
- Racks
- Mechanical and electrical plant
- Data Floor
- Operating Systems / Virtualisation
- Software (Solution Management)
- Business practices
- Security
For the avoidance of doubt these requirements do not cover cloud provision.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
External Standards | ||||||
In addition to the below requirements the following standards (or equivalent) MUST be adhered to and where appropriate, accreditation achieved with a valid certificate and a Statement of Applicability (SoA) and documented scope provided. | ||||||
| ES1.0 | NHS and social care data: off-shoring and the use of public cloud services guidance The geographical location (or specific range of locations) of the clinical data at rest and service management activities at any given time are to be known and communicated to the Authority. Operating the Solution or elements of the Solution outside of England will be with the permission of the Authority, the data controllers and their representative organisations. Note: There are no absolute barriers to the off-shoring of data or services, although the requirements of UK Government IA policy must be able to be met in the overseas location. See Data Protection Act and Offshoring for statements on the offshoring of information. | MUST | Self-certification with Supporting Evidence Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence could include:
|
| ES2.0 | Sanctions, embargoes and restrictions The Supplier will require approval from the Authority for any part of the Solution that is hosted or communicates with services outside of England. The communication between systems will not be made to those countries or states prohibited by Government Policy. | MUST | Self-certification with Supporting Evidence Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence could include:
|
| ES3.0 | Protect your organisation against cyber attacks. Cyber Essentials helps you to guard against the most common cyber threats and demonstrate your commitment to cyber security. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| ES5.0 | ISO 9001 - Quality management systems ISO 9001:2015 specifies requirements for a quality management system when an organisation:
All the requirements of ISO 9001:2015 are generic and are intended to be applicable to any organisation, regardless of its type or size, or the products and services it provides. | MUST | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. |
| ES11.0 | General Data Protection Regulation General Data Protection Regulation (GDPR) The Guide to the UK GDPR explains the provisions of the UK GDPR to help organisations comply with its requirements. It is for those who have day-to-day responsibility for data protection. The UK GDPR forms part of the data protection regime in the UK, together with the new Data Protection Act 2018 (DPA 2018). The main provisions of this apply, like the GDPR, from 25 May 2018. | MUST | Self-certification with Supporting Evidence Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence could include:
|
Physical Aspects | ||||||
This section is concerned with the physical aspects of a Data Centre including where the Data Centre is located, some of its physical attributes and factors near that data centre which could affect its operation and security. | ||||||
| HPA32.0 | Data Centre - declaration of Resilience: The Supplier’s Solution will provide at a minimum two separate geographically physical locations to hold the data and capability to run the services. The distance between the two locations will be such that they cannot both be affected by concurrent loss due to overlapping items on the Location Risk Assessment. | MUST | Self-certification | Self-certification | Self-certification |
IT Infrastructure | ||||||
This section is concerned with the physical infrastructure that makes up the service, how it is built and the policies around its setup. | ||||||
| HI13.0 | Live Service Separation: The Supplier will ensure that Live environments are segregated from the development activity by using processors, virtual servers, domains and partitions that are not in use by live and by storing development utilities away from the live environment. | MUST | Self-certification | Self-certification | Self-certification |
Servers | ||||||
This section is concerned with servers that provide clinical applications, including operating systems and use of virtualisation. | ||||||
| HS20.0 | Server Operational Design: Application Security: The Supplier will ensure that servers are configured to disable or restrict:
| MUST | Self-certification | Self-certification | Self-certification |
Network | ||||||
This section covers the use of networks in the provision of the Supplier’s service. The NHS Wide Area Network is now known as HSCN; referred to as the “NHS Network” below. The Health and Social Care Network (HSCN) is the successor to N3. In 2018 N3 was already closed to new implementations when The Authority published its 'Internet First' strategy. The strategy mandates that health systems should be designed to use the Internet rather than HSCN. | ||||||
| HNT1.0 | External Networking: The Supplier’s data centre to be connected to the Internet and the NHS Network, for clinical services holding PID that are accessed from either an Internet or NHS Network attached end point. | MUST | Self-certification | Self-certification | Self-certification |
| HNT7.0 | Data Centre Network Resilience: The data centre will have dual Internet and dual NHS Network connections via two exchanges, where available. | MUST | Self-certification | Self-certification | Self-certification |
Data Storage | ||||||
This section is concerned with how data is protected when a failure occurs within the Solution. This covers both clinical and non-clinical data. | ||||||
| HDP1.0 | Data Access Protection: The Supplier to ensure protection of clinical data at the storage level through the use of RAID, block snapshot, replication or mirroring technology within a single data centre / data hall. | MUST | Self-certification | Self-certification | Self-certification |
| HDP2.0 | Data Loss protection: The Supplier to ensure clinical data is protected using methods against up to two disk or media failures, within any one device configuration offering a discrete storage service. | MUST | Self-certification | Self-certification | Self-certification |
| HDP3.0 | Data Integrity Implementation: The Supplier will provide Transactional Integrity for clinical data by the use of a 2nd physical location for storing of data. Note: The 2nd site could be a DR Site, Active 2nd site or a site used for storage replication. | MUST | Self-certification | Self-certification | Self-certification |
| HDP5.0 | Data Handling Conformance: The clinical data transferred to additional locations will be stored in accordance of the Authority’s data handling policies. | MUST | Self-certification | Self-certification | Self-certification |
| HDP6.0 | Data Integrity Approach: The Supplier’s approach to Transaction Integrity to securing data to at least two separate physical locations to be communicated to and assured by the Authority at the Suppliers design stage. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| HDP9.0 | Data Replication: The Supplier will ensure that the clinical data applied to the primary site and sent to the 2nd site is processed in time order of how the data was applied to the primary site. Thus ensuring a consistent data set across the two sites and to maintain the application integrity. | MUST | Self-certification | Self-certification | Self-certification |
Reporting & Documentation | ||||||
| HD1.0 | Documentation: The Supplier will provide documentation which represents the non-functional technical architecture of the Solution, including but not limited to: data centre design, local and wide network architecture, and physical technology models. Documentation should include diagrams, and associated textual descriptions, as necessary to enable effective assurance of key Solution aspects as noted below:
Note: Document artefacts to be concise with a preference for diagrammatical form where the Supplier utilises as much of their own internal documentation as possible to reduce extra document production. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
Security | ||||||
Due to the sensitive nature of the information in this section, the details are held in the file "Co-location and Provider Data Centre Hosting & Infrastructure Requirements - Security" and can be requested by emailing england.buying.catalogue@nhs.net. | ||||||
| SEC1.0 | The Supplier will comply with all requirements in the "Co-location and Provider Data Centre Hosting & Infrastructure Requirements - Security" file. | MUST | Refer to “Co-location and Provider Data Centre Hosting & Infrastructure Requirements - Security” file for details. | Refer to “Co-location and Provider Data Centre Hosting & Infrastructure Requirements - Security” file for details. | Refer to “Co-location and Provider Data Centre Hosting & Infrastructure Requirements - Security” file for details. |
Information Governance¶
Supports the controls needed to ensure that Special Category Data is kept confidential, is accurate and is available to authorised users when required.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
Authentication and Identity Verification | ||||||
| GP-IG-2.1-3B | Authentication - General standards Any access to Personal or Special Category Data within Solutions will be subject to authentication at least to standards described in GP-IG-2.2-1. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.1-4 | Authentication - NHS authentication with no additional authentication Solutions shall ensure that, where NHS authentication (as per the Authentication and Access Standard) is used, those users are able to carry out all Solution activities (subject to their access rights) without the need for any additional authentication. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.1-10 | Authentication - Local Users not using NHS authentication (see GP-IG-2.1-4) can only use local authentication and will not therefore be allowed access to Solution functions for which NHS authentication is required. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.1-13 | Enable user role and organisation validation The application shall make it possible – by clearly and continually displaying the user’s name, role and organisation – for users to validate the role and organisation relevant to the access they are being granted so as not to be able to claim ignorance of that role or organisation, or otherwise justify a lack of awareness of the significance of their actions. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.1-14 | Audit authentication activity All activities associated with requirements in this section will be recorded in the Solution Audit Trail. Such Audit Trail entries can also include End User device (or Solution) identification information. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.3-1 | NHS Authentication The Solution will use the applicable NHS authentication service to provide authentication:
If the Solution cannot use any existing NHS Authentication, an alternative, standards-based Authentication service that delivers equivalent strength to be used. These cases are expected to be rare and will be reviewed on a case-by-case basis. | MUST | Self-certification Self-certification description to include:
| Self-certification Self-certification description to include:
| Self-certification Self-certification description to include:
|
| GP-IG-2.3-1A | NHS Identity Verification - NHS login service for Patients/Citizens The Solution will use NHS login service to provide Identity Verification for Patients/Citizens. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.3-2 | Authentication and Identity Assurance Access to confidential Patient information requires AAL2 level Authentication and Identity Assurance Level 3 (IAL3) at a minimum.
If the Solution cannot use any existing NHS Authentication, an alternative, standards-based Authentication service which is compliant with DAPB3051 is to be used. | MUST | Self-certification Self-certification description to include:
| Self-certification Self-certification description to include:
| Self-certification Self-certification description to include:
|
| GP-IG-2.3-3 | Application Access - Authentication Steps Users to be able to access all areas of the application applicable to their level of access after authenticating one time. In the case where a user needs to elevate their access from that of the initial authentication, an additional authentication challenge is to be used. e.g. subsequent Spine access, or taking on administrator function. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.2-2 | Local authentication - unique user identity and password Any local authentication will be based on a unique user identity which is then authenticated at least through the use of a password. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.2-3 | Local authentication - password strength and management Local authentication will satisfy the password strength and password management guidance set out in Meeting the Digital Service Standard and Password Guidance. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.2-4 | Password storage Where passwords are stored in Solution databases, they will be stored salted and hashed, using algorithms and strengths recommended in NIST Cryptography Standards. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.2-5 | User access and password Audit Trail Successful login, unsuccessful login attempts, logouts and password changes will be recorded in the Solution Audit Trail. Data to be included in such an Audit Trail entry: Successful login, logout:
Unsuccessful login:
Password changes:
Such Audit Trail entries to also include End User device (or Solution) identification information. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.2-6 | New user - password creation New users will be assigned, or will be required to enter, a password matching password-strength requirements in GP-IG-2.2-3. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.2-7 | New user - define own password on first use If initial password is assigned, the new user will be required to set a password that meets the password-strength requirements in GP-IG-2.2-3, upon first use of the Solution. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-2.2-8 | Password reset Password reset facilities are provided; the Solution will store additional information associated with each user so as to allow newly-generated passwords to be provided securely to devices previously known to be associated with the user (such as mobile number or NHSmail email address). Any such newly-generated passwords cannot be made visible to Solution-administration staff, and following first use of such passwords, the user will be required to set their own password. | MUST | Self-certification | Self-certification | Self-certification |
Role-based Access Control | ||||||
| GP-IG-3-2 | Role-based access control The Solution will have Role-based access control to authorise users’ access to the Solution functions and data. For NHS authentication requirements see Authentication and authorisation section of Interoperability Standard. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-3-7 | Updates to Job Role to Baseline Activities The Solution will have a process for incorporating updates to the nationally-defined mapping from Job Role to Baseline Activities as published by the Authority. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-3-8 | Local Role-based access control Where the Solution supports users who do not use NHS authentication, the Solution shall implement local Role-based access controls which support the allocation of access rights. These are in line with the nationally-defined job roles and activities taken from the latest National RBAC Database. Local RBAC mechanisms will need to:
Access controls to include the ability to segregate access to the following functions:
| MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-3-9 | Local authentication - local access rights Where Solutions provide local authentication (see GP-IG-2.2-1) that can be used by users who are enabled to use NHS authentication, any local access rights to automatically reflect the access rights associated with the user as defined on Spine, i.e. without any manual update mechanism being required and no increased access rights can be locally associated with the local based authentication. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-3-12A | Role-profile and Organisation Context matching The Solution will ensure that the Organisation Context of the Solution matches the selected role-profile. Where the Solution supports a single organisation, that organisation to match the organisation from the selected role-profile for any user access to proceed. Where a particular Solution supports multiple organisations, the Solution shall set the Organisational Context to that of the selected role-profile (and thus influencing the control as to what Personal Data the user has access to). | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-3-13 | Provide local Solution functions to RBAC mappings Suppliers will provide details of the mapping of their local Solution functions to activities from the National RBAC Database. This is to support the Registration Authority (RA) process (to ensure that RAs have information to enable them to correctly define positions and allocate users to such positions, or by allocating users individual User role-profiles containing appropriate job roles and any additional activities) and also to support the compliance process. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-3-17 | Activities restricted to logged in user role The Solution can only support the activities associated with the role that the user has logged in under. The Solution will not combine activities from multiple roles for the purposes of controlling a user’s access to the Solution. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-3-19 | Specific professional status The Solution will support the notion of specific professional status for users, to support areas of functionality where there can be, for example, statutory reasons to restrict such functionality to certain professional groups (for example where fit notes can only be issued by GPs). | MUST | Self-certification | Self-certification | Self-certification |
Legitimate Relationships | ||||||
| GP-IG-4-3 | Access to the records of non-active Patients/Service Users Access to the records of non-active Patients/Service Users can be provided within a grace-period following inactivation (such a period to be configurable per organisation, default 4 weeks):
| MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-4-4 | Reactivate Patient/Service User record - alert The act of making a Patient/Service User record active (from an inactivated or archived state), when carried out without a formal Patient/Service User re-registration, will generate an alert to the user designated as the organisation’s Privacy Officer (see Notifications). | MUST | Self-certification | Self-certification | Self-certification |
Information Sharing across Organisations for Direct Care | ||||||
“safe and appropriate sharing in the interests of the individual’s direct care should be the rule, not the exception” There are different ways in which information is commonly shared across organisations; for example:
The requirements in this section are intended to recognise that:
| ||||||
| GP-IG-5-1 | Data sharing - recording Patient/Service User expressed preferences Solutions will provide the capability to record a Patient/Service User’s expressed preferences as to how clinical information about them, can be accessed from other care settings, for their direct care. Where Solutions are directly used in other care settings, it is expected that such preferences can be managed at the level of individual operational units or settings in which Patients/Service Users would reasonably expect their information to be shared without hindrance, in order to support their direct care. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-5-2 | Organisational change - Patient/Service User preferences carried forward Organisational structures change over time, for example as Practices merge or split. In such circumstances, every Patient/Service User’s expressed preferences will be carried forward into the new organisational structure, on the basis that Patients/Service Users have been made aware of the implications of any such proposed change, prior to it taking place, and that Patients/Service Users had the opportunity to amend their expressed preference. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-5-3 | Practice controlled information sharing The Practice is to have control as to whether information sharing (access to information from other care settings) for any Patient is enabled, so as to align with Confidentiality: Good Practice in handling Patient information. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-5-4 | Respect recorded preferences The Solution will respect any such recorded preferences, having effect on the sharing of information that might otherwise be technically possible. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-5-5 | Preferences for sharing data into the Organisation from other care settings If the Solution also supports access to information from other care settings, then it will need to also support the recording (and respect of) expressed preferences whether information about them from specific other organisations can be viewed from within the Organisation. It is not necessary that an explicit consent to such sharing be recorded within the Solution prior to any such sharing taking place, other than the exception condition described in requirement GP-IG-5-6A. | SHOULD | Self-certification | Self-certification | Self-certification |
| GP-IG-5-6A | PDS - express dissent setting Some Patients/Service Users have an “express dissent” setting (value 2) on the consent-to-share flag held nationally on PDS, to be interpreted that the Patient/Service User has previously expressed concern about potential information sharing for their direct care across different care settings. For such Patients/Service Users, making their Personal Data available to other care settings will need to be on an “opt-in” basis, rather than the default “opt-out”. Therefore, in that situation, Solutions will have to prevent any access to information from other care settings, unless the Patient/Service User has explicitly consented to such sharing in the local Solution through facilities provided in requirement GP-IG-5-5. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-5-6B | Information sharing prompt In circumstances where both (i) the Patient/Service User has an ”express dissent” (value 2) setting nationally, and (ii) the Solution has not recorded any expressed decisions from the Patient/Service User, the Solution will prompt the Clinician as part of an encounter with the Patient/Service User, to provide an opportunity to confirm the Patient/Service User’s intentions through the facilities described in requirement GP-IG-5-5. | MUST | Self-certification | Self-certification | Self-certification |
Additional Privacy Controls | ||||||
| GP-IG-17-1 | Access to whole Records It will be possible to:
| MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-17-2 | Access to individual parts of records It will not be possible, over and above the use of RBAC in general:
| MUST | Self-certification | Self-certification | Self-certification |
Provenance | ||||||
| GP-IG-10-1 | Record provenance details for all Personal and Special Category Data The Solution will record the following provenance details of all Personal and Special Category Data recorded within the Solution:
The Solution will also make access to this information available to users. Whilst some details (such as name, role) associated with individual users are likely to change over time, the display of user information will reflect the state of such information as it was at the time of the associated event (such as data entry). | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-10-2 | Record provenance details of information shared across Organisations The Solution will record provenance details of information being sent, together with provenance details of information that might be entered into the Solution, based on incoming information. For example, a document from a separate, sending Organisation can be sent into the receiving Organisation, and some summarisation activity can then take place within the receiving Organisation. The Solution to record:
| MUST | Self-certification | Self-certification | Self-certification |
Data Suppression & Removal | ||||||
| GP-IG-11-1 | Prevent removal of Personal Data Other than in the specific circumstances described in subsequent requirements in this section, the Solution will NOT allow any user to remove Personal Data, for example from the electronic Patient/Service User record (whether that be a “logical delete/soft delete” causing information to be hidden from view, or a “physical delete/hard delete” causing information to be physically deleted from the clinical data repository). | MUST | Self-certification | Self-certification | N/A |
| GP-IG-11-3 | Logical deletion The Solution will provide the ability for users to “logically delete” entries in a record, i.e. resulting in the underlying data being marked in such a way that it is no longer visible to any user of the record. The requirements associated with this functionality vary, according to whether the information being deleted has been able to be viewed by other users (or accessible by Solution processes). If such data has not been viewable (for example where a user discovers during the recording of a Consultation that they are entering data in the record of a different Patient/Service User, or where the user recognises they have made an error):
Alternatively, where data is being logically deleted that has previously existed in the record, and has been accessible to other users (for example where a Patient/Service User feels that information in the record is damaging, that an annotation is not sufficient, and requests that information from the record is deleted; note that this is most likely to be true where information has been previously entered into the record in error):
| MUST | Self-certification | Self-certification | N/A |
| GP-IG-11-4 | Physical deletion The Solution will support the physical deletion of records or parts of records in response to court orders or other legislative circumstances. This functionality will NOT be made available to normal users of the Solution, and local Solution administrators will NOT be able to grant access to such functionality to normal users. Such physical deletions are expected to be rare – the functionality described in requirement GP-IG-11-3 is expected to satisfy the great majority of scenarios. Therefore, physical deletion shall be initiated through a Supplier’s service desk facilities, but shall only be carried out in response to a specifically authenticated and validated request from an organisation’s Caldicott Guardian or Privacy Officer, co-signed by a senior Clinical representative. Such requests shall be audited and retained by the Supplier. In such circumstances it will NOT be possible for any user, or back-office process, to reconstitute the state of the record to that prior to any such physical deletion. This functionality will NOT modify the Solution Audit Trail, other than is necessary to support this requirement. The fact of a physical deletion (without referring to data content) will be recorded in the Solution Audit Trail but such entries will NOT be visible to normal users of the Solution. | MUST | Self-certification | Self-certification | N/A |
There are several related mechanisms defined in requirements, which are compared in the following table:
Name | ID | Level | Typically initiated by | Actioned by | Reversible? | Visible marker of use? | Example/use case |
|---|---|---|---|---|---|---|---|
GP-IG-11-3 | MUST | User (during data entry) User or Patient for previously-committed data | User | Yes, by back-office | Yes, for previously-committed data | i) Clinician discovered error during data entry ii) Patient wishes damaging information to be hidden from all future users; Clinician agrees that this will not impact future case | |
GP-IG-11-4 | MUST | Patient | Back-office | No | No | Patient wishes damaging information to be hidden from all future users; court so orders. |
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
Audit | ||||||
| GP-IG-12-1 | Audit trails Solutions to provide Audit Trails, sufficient to support the following purposes:
Application level Audit Trails to be subject to the same level of controls as the electronic Patient/Service User record. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-2B | Include all information about exchanges with external Solutions and organisations in Audit Trails The Solution shall ensure that Audit Trails are kept which record information about all information exchanges with external Solutions and organisations, including but not limited to:
Such Audit Trails shall provide a security record for use in analysing breaches of security and policy that might be used as evidence for use in disputes. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-3 | Viewing Patient/Service User record as per previous date A means of viewing or reconstructing any individual Patient/Service User record as it was on any previous date will be supported, taking into account the requirements stated in GP-IG-11-4. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-4 | View/filter/sort Audit Trails The Solution shall provide facilities to allow authorised users (e.g. a Caldicott Guardian or Privacy Officer) to view Audit Trails. Such facilities to include the ability to display, filter and sort parts of the Audit Trail based on at least the following parameters (both individually and in combination):
Whilst some details (such as name, role) associated with individual users are likely to change over time, the display of user information to reflect the state of such information as it was at the time of the associated event (such as data entry). | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-5 | Audit Trail minimum information The Audit Trail records provided for GP-IG-12-1 and GP-IG-12-2B shall include the following minimum information:
Audit Trail records to include details of the End User device (or Solution) involved in the recorded activity. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-7 | Deleting Audit Trails The Solution shall ensure that records in the Audit Trail can only be deleted by a privileged user under specific conditions; such as court orders. Note that such deletions are expected to be very rare, and it is important that access to such functionality will be stringently controlled. It will not be possible for any local user to have such rights as a matter of course, and it will not be possible for any local administrator to be able to grant such rights to any local user. Any attempts to manually update or add to the Audit Trail to be prevented as far as is practicable, to ensure the integrity of the Audit Trail, and protect against attempts to tamper. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-8 | Audit Trails enabled at all times All Audit Trails shall be enabled at all times and there shall be no means for users, or any other individuals, to disable any Audit Trail. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-9 | Audit Trails included in routine Solution backup All Audit Trails shall be included as part of the routine Solution backup. This shall include:
| MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-10 | Audit retention The Audit Trail can be moved to archive storage as required for efficient Solution operation. This shall be retained in accordance with the audit retention policy; as specified in Records Management Code of Practice for Health and Social Care 2021 (or later) to allow access as specified above in requirement GP-IG-12-4. Where audit data has been previously archived, it will be made clear in audit viewing tools or other arrangements that some audit data might not be immediately available, but that it can be retrieved (with an indication of steps to take to make such archived data visible). | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-11 | Audit trail copies Copies of the Audit Trail to support the following:
| MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-12-13 | Link archived records to Audit Trail In a Solution where any Patient/Service User records are archived (made inaccessible to normal Solution access) then a link will be maintained between the archived records and the Audit Trail, to ensure that the audit records associated with archived records remain accessible. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-17-3 | Timestamp format The timestamps in Audit Trail entries shall be stored in UTC, to the nearest millisecond. When displaying audit entries to authorised users, they shall be displayed by default in local time (with clear indication how this will differ from UTC). | MUST | Self-certification | Self-certification | Self-certification |
Notifications | ||||||
| GP-IG-13-1 | Inform user notification will be generated There are a number of requirements elsewhere in this document (which reference this Notifications section) where it is appropriate for specific actions to be permitted, but a notification to a Privacy Officer will be raised to ensure appropriate governance of actions can be maintained. In such circumstances, the Solution shall ensure that the user is made aware that a notification will be raised, and is provided with the ability to enter a reason for their action. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-13-2A | Notification content In such circumstances, a notification containing the following information will be made available to the individual within the organisation designated as Privacy Officer:
| MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-13-3 | Levels of notifications The mechanism shall support at least two levels: notifications (warnings) and full alerts. Notifications are for occasions when there is a legitimate, but unusual, activity taking place (such as the access to a record of a newly-archived Patient/Service User) whereas alerts are for exceptional conditions (such as accessing record of Patient/Service User that has been deducted for some time). | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-13-4 | Privacy Officer requirements The Solution will allow the designated Privacy Officer to:
| MUST | Self-certification | Self-certification | Self-certification |
Data Subject Access Requests | ||||||
| GP-IG-15.8 | Support Response to Subject Access Requests The Supplier shall ensure that the Solution supports responding to Data Subject Access Requests (e.g. by providing the required data) in accordance with the ICO GDPR guidance regarding a data subject’s right to access. Any historical Personal Data, that can be linked to the current active record (for example as a result of a GP2GP transfer) although not normally available to Solution users, falls within the scope of a Data Subject Access Request. See right to rectification / erasure guidance. | MUST | Self-certification | Self-certification | Self-certification |
UK General Data Protection Regulation (UK GDPR) | ||||||
| GP-IG-16-1 | UK General Data Protection Regulation (UK GDPR) Suppliers to ensure that Solutions processing (including storage of) Personal or Special Category Data adhere to UK General Data Protection Regulation (UK GDPR). See General Data Protection Regulation guidance and ICO - Guide to the General Data Protection Regulation (UK GDPR) for further guidance. | MUST | Self-certification | Self-certification | Self-certification |
Information Security | ||||||
| GP-IG-14.2-2 | Protection from Unauthorised Access - Solution's databases and/or files The Solution shall ensure that all Personal and Special Category Data, and audit logs, are protected from unauthorised access and modification when stored within the Solution's databases and/or files. This applies wherever such data is being processed or stored. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.2-3 | Protection from Loss or Theft While being processed, stored, and in backup and archive storage, all Personal Data and sensitive Personal Data and audit logs shall be physically protected from loss or theft in line with Records Management Code of Practice for Health and Social Care 2021 (or later). | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.2-4 | Personal Data and Sensitive Personal Data - retention policy Personal Data and sensitive Personal Data and audit logs shall be retained in line with Records Management Code of Practice for Health and Social Care 2021 (or later). | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.2-5 | Data Storage - Location The location of physical storage of Personal or Sensitive Personal Data shall abide by published Health and Social Care Cloud Security - Good Practice Guide and described in the Records Management Code of Practice for Health and Social Care 2021 (or later) or as subsequently amended. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.2-6 | Non-Personal Data - Retention Policy All non-personal data shall be retained in line with the latest version of the Records Management Code of Practice. See GP-IG-14.2-4 for Personal Data and Special Category Data - Retention Policy. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.2-7 | Data - secure deletion When no longer required to support services, all media and any infrastructure components that have stored data shall be subject to secure deletion to standards described in NIST Guidelines for Media Sanitization. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.3-1 | Limit Personal Data Transferred to Portable Media The Supplier shall demonstrate that it has limited any Personal Data transferred to portable media to the minimum required. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-18-5 | Encrypt Portable Media Where devices or services offered by the Supplier result in the transfer of any Personal Data on any portable media, such media shall be encrypted. The level of encryption used shall conform to the NIST Cryptography Standards to ensure only approved algorithms are used. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-18-6 | Data Transfer - encryption Where devices or services offered by the Supplier result in the transfer of any Personal Data outside the local physical or virtual network, including transfers across network boundaries within a single local network or exporting data to removable data, encryption shall be used. The level of encryption used shall conform to the NIST Cryptography Standards to ensure only approved algorithms are used. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.3-4 | Audit - encryption, decryption, transport, storage and destruction of data The encryption, decryption, transport, storage and destruction of data which is physically transferred shall be auditable with the media logged and tracked to ensure all instances are accounted for. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.3-5 | Encryption Accredited to FIPS 140-2 The Supplier shall ensure that the encryption product used is accredited to FIPS 140-2. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-18-7 | Encryption Keys - strength and complexity The Supplier shall ensure that the encryption key for each archive is of an appropriate strength conforming to NIST Cryptography Standards to ensure only approved algorithms are used. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.3-7 | Encryption Keys - Provide to Data Controller for Encryption Operations Where encryption keys are generated by the Solution automatically for transfer of data by portable media, the Solution shall provide the encryption key to the Data Controller for each encryption operation. In such circumstances, cryptographic keys will not be generated by the use of an algorithm or other shared secret that solely combines known or accessible environmental or other context-specific information, without the inclusion of unique, context specific secret information as provided by the user or Supplier. Such encryption keys shall be generated using existing libraries. Context specific, secret information to be controlled and managed in line with key management good practice principles (i.e. with audited access controls in place). | MUST | Self-certification | Self-certification | N/A |
| GP-IG-14.3-8 | Encryption Keys - secure storage The Supplier shall ensure that any encryption keys generated by the Solution are stored securely to enable data recovery in the event of key loss or corruption by the Data Controller. Encryption keys are to be stored separately from the data they protect. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.3-9 | Encryption Keys - unique per data archive The Supplier shall ensure that the encryption key for each archive is unique to that data archive. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.3-10 | Encryption Keys - separate communication mechanism Where the Supplier Solution provides a mechanism for sending encryption keys to a recipient, either electronic or manually, there are processes in place to ensure that the encryption keys are sent following a separate communication mechanism to the encrypted data or posted separately from the encrypted media. | MUST | Self-certification | Self-certification | N/A |
| GP-IG-14.3-11 | Transfer of Personal Data - Portable Media Where a service offered by the Supplier requires the transfer of Personal Data by portable media the media shall be encrypted to the level required by the NIST Cryptography Standards and transported in a secure manner. The transfer of Personal Data shall also be conducted using Secure Courier services following NIST Cryptography Standards. | MUST | Self-certification | Self-certification | N/A |
| GP-IG-14.3-12 | Transfer of Personal Data - Electronic Means Where a service offered by the Supplier requires the transmission of Personal Data by electronic means, the data shall be transmitted in an encrypted form to the level required by the NIST Cryptography Standards. This encrypted data can be transmitted via a secure email service such as NHS Mail or over an approved network such as HSCN. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.3-13 | Protect Personal Data - un-trusted networks The Solution shall protect the confidentiality and integrity of Personal Data in transit across un-trusted networks, including (but not limited to):
| MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.4-2 | Connections to Remote Servers and Applications - authenticated The Supplier shall ensure that all connections to remote servers and applications are authenticated. This requirement includes connections via the Internet. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.4-3 | Access to Diagnostic Ports - securely controlled The Supplier shall ensure that access to diagnostic ports for network and server components is securely controlled. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-14.4-4 | Segregate Networks and Servers The Supplier shall segregate the networks and servers that support services under these contractual arrangements from deployments relating to other, unrelated services. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-16-4 | ISO/IEC 27001 Accreditation Provide either a: Valid ISO 27001 Certificate from a UKAS-registered accreditation organisation, or IAF registered accreditation organisation in exceptional circumstances. or Implementation plan to achieve ISO 27001 Certification from a UKAS-registered accreditation organisation, or IAF registered accreditation organisation in exceptional circumstances. | MUST
| Self-certification with Supporting Evidence Supporting evidence to include one of the following:
| Self-certification with Supporting Evidence Supporting evidence to include one of the following:
| Self-certification with Supporting Evidence Supporting evidence to include one of the following:
|
| GP-IG-16-5 | Cyber Essentials Plus The Supplier will ensure they comply with Cyber Essentials Plus to protect their organisation against cyber attacks. Cyber Essentials helps you to guard against the most common cyber threats and demonstrate your commitment to cyber security. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| GP-IG-18-1 | DSP Toolkit Suppliers to complete the Data Security and Protection Toolkit online self-assessment to provide assurance that they are practising good data security and that Personal Data is handled correctly. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| GP-IG-18-8 | National Data Guardian Security Standards The Supplier shall ensure they comply with the National Data Guardian's Data 10 Security Standards. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-18-2 | Antivirus and Malware The Supplier shall ensure that Anti-malware software is deployed on all appropriate endpoints and kept up to date. Where it is deemed inappropriate other protections must be in place to mitigate the risk of malware affecting the operation of the system, such as increased auditing and the use of Intrusion Detection Systems (IDS) and/or Intrusion Prevention Systems (IPS). See Guide to Malware Incident Prevention and Handling for Desktops and Laptops for further guidance. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-18-3 | Application Security The Supplier will ensure that applications are appropriately protected using industry standard techniques, such as controlled access to standard ports and APIs, applying Least Privilege, accepting only encrypted connections, input validation, and fail-safe defaults. The Supplier will be aware of common specific application vulnerabilities and will ensure all appropriate mitigations are incorporated in their architecture. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-18-4 | Patch Management The Supplier shall ensure that vendor patches are applied as soon as reasonably possible. Where a 3rd party (such as a hosting company) is responsible for patching the Supplier shall ensure that they are subscribed to receive all patches in a timely manner. See Guide to Enterprise Patch Management Technologies for further guidance. | MUST | Self-certification | Self-certification | Self-certification |
| GP-IG-18-9 | Penetration Testing Penetration testing will be completed by a 3rd party CHECK / CREST accredited organisation before go-live and annually thereafter. An action plan must be in place to mitigate any vulnerabilities identified in an appropriate timeframe. | MUST | Full Assessment Supporting evidence to include:
Ongoing Compliance:
| Full Assessment Supporting evidence to include:
Ongoing Compliance:
| Full Assessment Supporting evidence to include:
Ongoing Compliance:
|
| GP-IG-18-10 | Use of links and attachments in Patient communications Where links or attachments are included in communications, the Supplier must take steps to ensure they are safe and free from malware. For links this must be done on an ongoing basis to ensure that the site poses no danger to the recipient even after the link is sent. | MUST | Self-certification | Self-certification | Self-certification |
Interoperability Standard¶
Defines overarching Interoperability requirements and interfaces to be implemented, including quality and principles to be followed for Supplier Solutions.
Interoperability non-functional requirements¶
The following overarching requirements apply to all interfaces in the scope of the Interoperability Standard which are offered by a Solution.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
| ISNFR01 | Suppliers will implement uplifts to the message & API specifications included within the interoperability Standard as agreed & directed by the ‘Minor or patch changes’ section of the Change Management Process. | MUST | Self-certification | Self-certification | Self-certification |
| ISNFR03 | Suppliers will provide the full documentation for all currently live or in development and available-to-consumers interfaces, under a Creative Commons Attribution-NoDerivatives 4.0 International License. Documentation must include, but is not limited to:
| MUST | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| ISNFR04 | For all currently live or in development and available-to-consumers interfaces, Suppliers will provide mock versions of the interfaces to support Consumer development and testing. Mocks must meet the following criteria:
| MUST | Self-certification | Self-certification | Self-certification |
| ISNFR05 | Discrepancies discovered between ISNFR04 test mocks and behaviour of live interfaces will be rectified within two working days of first notification to the interface Provider. | SHOULD | Self-certification | Self-certification | Self-certification |
| ISNFR06 | Discrepancies discovered between ISNFR03 documentation and actual interfaces will be rectified within 5 working days of first notification to the interface Provider. | MUST | Self-certification | Self-certification | Self-certification |
| ISNFR07 | Within the scope of interfaces specified within the Standard, Suppliers must not offer differential service, e.g. all API functionality and behaviour will be equally available to all API Consumers, including the API Provider's own applications. | MUST | Self-certification | Self-certification | Self-certification |
| ISNFR08 | Suppliers should not offer multiple APIs for the same purpose, e.g. there should not be multiple, different Appointments Booking APIs. Suppliers are free to offer APIs to different Consumers under different commercial terms if permitted by the contract and Contracting Vehicle, but they should offer only one technical API for each purpose. | SHOULD | Self-certification | Self-certification | Self-certification |
Minimum non-functional requirements for interfaces built to the Authority's specifications¶
Where an interface/extract is built to the Authority's functional specifications, e.g. IM1 - Interface Mechanism or GP Connect, the following requirements apply to the production implementation. For requirements relating to performance and availability Suppliers should refer to the Service Levels.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
| ASNFR01 | Data currency. Updates to systems made through non-API mechanisms (e.g. user interface) should be available on APIs in real time, i.e. as soon as the update transaction is committed. | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| ASNFR02 | Data currency. Updates made through APIs must be available on APIs in real time, i.e. as soon as the update transaction is committed. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
Non-Functional Questions¶
Enables The Authority to assess the risk associated with the Compliance Assessment of the Solution against appropriate Overarching Standards.
Applicable Contracting Vehicle(s) | ID | Requirement | Category A | Category B | Category C |
|---|---|---|---|---|---|
Resilience | |||||
| GP-NFQ-RS-5 | Component Failure Impact Analysis Describe what CFIA documentation has been produced? | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| GP-NFQ-RS-3 | Software Design Describe what level of resilience is provided in the software design? | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
Service Management | |||||
| GP-NFQ-SM-3 | Monitoring Describe what are the key resources, services and performance indicators that can be monitored? | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| GP-NFQ-SM-4 | Alerting Who is alerted if a resource or service is not meeting the agreed service levels? | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| GP-NFQ-SM-7 | Event logging What events are logged? | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
Capacity Management | |||||
| GP-NFQ-CM-3 | Capacity Management toolset What Capacity Management toolset is implemented and what is the scope of information capture available. | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| GP-NFQ-CM-4 | Capacity Management Describe how the capacity of the Solution is managed and the associated reports that are produced, include management and solution process models. | Full Assessment Supporting evidence to include:
Additional supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Additional supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Additional supporting evidence could include:
|
Integrity | |||||
| GP-NFQ-I-1 | Message Accuracy and Transfer Describe how message accuracy and transfer is achieved and maintained (e.g. how is the data guaranteed not to be corrupt). | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
Service Management¶
Sets out the requirements for Suppliers with regards to the delivery and management of services that support and provide their Solutions.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Applicable to Type 1 and/or Type 2 Catalogue Solutions | Category A | Category B | Category C |
|---|---|---|---|---|---|---|---|
| SM005 | The Supplier shall comply with the following Service Management Agent's documents: | MUST | Both | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| SM005a | The Supplier shall comply with the following Catalogue Authority documents: | MUST | Type 2 only | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| SM006 | The Supplier shall measure the performance of each Catalogue Solution against each of the Service Levels applicable to the Catalogue Solution. | MUST | Both | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| SM006a | The Supplier shall measure the performance of each Catalogue Solution against each of the Service Levels applicable to such Catalogue Solution as set out in the Catalogue Solution Service Levels document. | MUST | Type 2 only | Full Assessment Supporting evidence to include:
| Full Assessment Supporting evidence to include:
| Self-certification |
| SM007 | The Supplier shall operate a process for managing Planned Downtime in accordance with the requirements for the same set out in the relevant Catalogue Solution Service Levels document. | MUST | Type 1 only | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| SM007a | The Supplier shall operate a process for managing Planned Downtime in accordance with the requirements for the same set out in Catalogue Solution Service Levels document. | MUST | Type 2 only | Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification |
| SM013 | The Supplier shall ensure that all data used within the Supplier Service Management Toolsets and Supplier Performance Management Toolsets is retained for a minimum of two years or the duration of the Call Off Agreement (whichever is longer) in a manner that can be accessed by the Supplier and provided to the Service Management Agent within 48 hours of any request. | MUST | Both | Self-certification | Self-certification | Self-certification |
| SM014 | To the extent the Service Management Agent can not access data as required, the Supplier must make such data available to the Service Management Agent no later than 24 hours after the Service Management Agent has requested such data (this time period excludes weekends and Bank Holidays), or where that the data is required urgently (such as to respond to a Parliamentary question), no more than 4 hours from the request being made by the Service Management Agent to the Supplier. The Service Management Agent shall act reasonably and give due regard to the impact on the Supplier when making such requests. | MUST | Both | Self-certification | Self-certification | Self-certification |
Testing¶
Ensures that Suppliers' software delivery test processes are of sufficient quality and rigour.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
|---|---|---|---|---|---|---|
Testing Requirements | ||||||
| TEST-1 | Irrespective of the Software Development Life Cycle (SDLC) implemented (traditional Waterfall to Agile), there will be organisational and project specific test processes underpinned by appropriate artefacts. Example evidence could include but not constrained to:
How are different types of testing either within a traditional SDLC or within Agile iterative-incremental development established, such as:
How testing automation is incorporated into the software build and distribution process, such as continuous build integration:
| MUST | Full Assessment Supporting evidence to include:
| Self-certification | Self-certification |
| TEST-2 | There will be Test Management Processes covering test planning and design. Example evidence could include:
| MUST | Full Assessment Supporting evidence to include:
| Self-certification | Self-certification |
| TEST-3 | There will be Test Management Processes covering test execution and management. Example evidence could include:
| MUST | Full Assessment Supporting evidence to include:
| Self-certification | Self-certification |
| TEST-4 | There will be Test Management Processes covering test completion and Reporting. Example evidence could include:
| MUST | Full Assessment Supporting evidence to include:
| Self-certification | Self-certification |
Test Environments Requirements | ||||||
| TEST-ENV-1 | The Supplier whose solution interoperates with the NHS national services and the applicable Non-Overarching Standards will provide the Authority with access to their system test instance(s), for assurance of the Capabilities and Non-Overarching Standards under the Contracting Vehicle. | MUST | Full Assessment Supporting evidence to include:
Note: The system software test instance(s) should be separate from the system software development instances, to support the testing and assurance activities of the Authority and other third party consumer Suppliers who would need to interoperate with the system software test instance(s) using the Non-Overarching Standards APIs. | N/A | N/A |
| TEST-ENV-2 | The Supplier will make access available to the requested version(s) of system test instance(s) within two weeks of the date of request by the Authority. These versions could either be compliant or versions for which compliance is being sought. | MUST | Self-certification | N/A | N/A |
| TEST-ENV-5 | The Supplier will ensure that a non-functional test environment is available to do Volumetric and Performance testing for their Solution. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| N/A | N/A |
| TEST-ENV-6 | The Supplier will provision and support system test instances for User Acceptance Testing (UAT) and for training of End Users, enabled with all the Capabilities and national service integrations as per the Non-Overarching Standards under the Contracting Vehicle. Such instances shall be separate from the system test instance(s) provisioned to the Authority. | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| N/A | N/A |
| TEST-ENV-7 | The Supplier will ensure that their test environment(s) and system test instance(s) support robust access and security controls both at Solution level and Infrastructure level, so that only authorised users can access the test environment(s) and system test instance(s). | MUST | Self-certification with Supporting Evidence Supporting evidence to include:
| N/A | N/A |
| TEST-ENV-8 | The Supplier will ensure that the test environment is, as a minimum, available on all the working days of a week between 8 am to 6 pm. Any scheduled downtimes for undertaking maintenance activities should preferably be slotted outside the working hours and be notified to the Authority a couple of weeks in advance, to minimise the impact on ongoing or scheduled testing and assurance activities either being undertaken by the Authority or the connecting system suppliers. Any downtime required for deployment of emergency patch releases, should be notified to the Authority prior to the deployment. | MUST | Self-certification | N/A | N/A |
| TEST-ENV-9 | The Supplier will provide at least a minimum test data set (such as admin users, reference data such as user roles and access privileges, clinical reference dataset and any other applicable reference data sets etc.) for the Authority to be able to perform testing and assurance activities and to perform any basic admin tasks on the system test instance(s). The test data will contain Synthetic Data only. It will not contain any sensitive or personally identifiable Patient data. The Supplier will ensure that any maintenance releases/emergency patches deployed to their test environment does NOT erase any of the existing test data created by the Authority as this might adversely impact any ongoing testing and assurance. | MUST | Full Assessment Supporting evidence to include:
| N/A | N/A |
| TEST-ENV-10 | The Supplier will ensure that the system test instance(s) are capable of supporting concurrent testing by multiple external connecting system suppliers, where applicable under the Contracting Vehicle, allowing each to test independently of the others. | MUST | Full Assessment Walkthrough of the provisioned test environment(s)/system test instance(s) in an online session | N/A | N/A |
| TEST-ENV-11 | The Supplier will support backup and restore functions, to allow restoration of their system test instances(s) back to the original clean state or a previously backed-up state, if required. | MUST | Self-certification | N/A | N/A |
| TEST-ENV-12 | The Supplier will ensure that the performance of their system test instance(s) is comparable to the production system instance, albeit for the restricted volumes in the Test environment, in order to provide a realistic expectation of performance behaviour in the LIVE estate. | MUST | Self-certification | N/A | N/A |
| TEST-ENV-13 | The Supplier will provide all the necessary technical documentation for their provisioned API interfaces or bulk data interfaces to allow integration testing with external connecting supplier systems, where applicable to the Contracting Vehicle. | MUST | Full Assessment Supporting evidence to include:
| N/A | N/A |
| TEST-ENV-14 | The Supplier will provide the necessary guidance and access privileges to the Authority for interrogating Audit Trail records, system logs and API messaging logs which might aid the Authority in independent identification of any technical integration issues to minimise reliance on the Supplier. The Supplier will provide all the necessary support to the Authority in identifying and resolving any technical integration issues encountered during the testing and assurance activities. | MUST | Self-certification with Supporting Evidence
| N/A | N/A |
| TEST-ENV-15 | The Supplier will provide contact details of their system help desk or the team who are accountable for logging and resolution of any test environments(s) or system test instance(s) issues or incidents. The Supplier should advise the Authority of the process for logging the issues or incidents, and the expected timescales for resolution based on severity/criticality. | MUST | Self-certification | N/A | N/A |
Live Environments Requirements | ||||||
| LIVE-ENV-1 | The Supplier will support use of appropriate and limited Synthetic Data in their production (live) environment to support any smoke testing of the software build in the production (live) environment. It will be possible for the synthetic test patients to be clearly demarcated from the real patients. | MUST | Self-certification | N/A | N/A |
Training¶
Defines the training activities and collateral expected from Suppliers to support the buyers and users of their Solutions.
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Self-directed | Category A | Category B | Category C |
|---|---|---|---|---|---|---|---|
Training Exemption | |||||||
| TR-1.1 | Training Exemption - Template If the Supplier does not intend to deliver training, they will complete the Supplier Training Exemption template justifying why. The exemption will be reviewed and approved by The Authority. Training includes, but is not limited to, the following delivery methods:
| MUST | Yes | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
Compliance | |||||||
| TR-2.1 | Information Governance Standard Compliance The Supplier shall comply with the Information Governance Standard:
| MUST | Yes | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| TR-2.2 | Supplier Accountability & Responsibility Regardless of whether it is the Supplier itself or their sub-contractor providing all or elements of the training services outlined, the Supplier shall maintain accountability and responsibility for the deliverables and training delivery. If the Supplier is intending to use sub-contractors, they will confirm compliance or intended compliance to this requirement in the agreed Training Plan. | MUST | Yes | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
Training Plan | |||||||
| TR-3.1 | Training Plan - Training approach The Supplier shall provide a documented Training Plan which details their approach to training for all Capabilities being supplied, using the template provided by The Authority. It must include all the information contained in the template. The Training Plan will be agreed with The Authority. | MUST | Yes | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
Training Materials and Design | |||||||
| TR-6.1 | Training Materials - Delivery The Supplier shall deliver a complete set of relevant training materials to the Local Organisation/End Users, for each Capability. These shall be reviewed and agreed by the Local Organisation/End Users as fit for purpose. They shall be provided at an agreed timescale, prior to the delivery of training and be version controlled. The materials and delivery methods will comply with relevant legislation, for example, The Equality Act 2010, Copyright, Data Protection Act 2018, UK General Data Protection Regulation and Health and Safety at Work Act. The Supplier shall document their intended methods and approach in the agreed Training Plan. | MUST | Yes | Full Assessment Supporting evidence to include:
Additional supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| TR-6.4 | Training Resources - Sample review | MUST | Yes | Self-certification Ongoing compliance:
| Self-certification Ongoing compliance:
| Self-certification Ongoing compliance:
|
Training Personnel | |||||||
| TR-8.1 | Training Personnel - Skills, experience and knowledge The Supplier shall ensure that its training personnel have:
The Supplier will:
| MUST | Yes | Full Assessment Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
| Self-certification with Supporting Evidence Supporting evidence to include:
|
| TR-8.3 | Training Personnel Issues When issues on the Supplier’s trainers’ delivery and knowledge are identified and agreed to be inadequate, the Supplier will provide additional training, if required, at no cost. The Supplier will provide additional training if required based on:
| MUST | No | Self-certification | Self-certification | Self-certification |
Training Environments | |||||||
| TR-9.1 | Training Environment - Provision The Supplier shall provide a training environment which mirrors the live system and uses dummy data. The training environment shall be in place before the training commences. The Supplier will confirm compliance or intended compliance to this requirement. The Supplier will provide details of the training environment with realistic data sets which meet information governance requirements and details of how the training environment is refreshed, reset and maintained in the agreed Training Plan. | MUST | No | Full Assessment Supporting evidence to include one of the following:
| Self-certification with Supporting Evidence Supporting evidence to include one of the following:
| Self-certification with Supporting Evidence Supporting evidence to include one of the following:
|
Evaluation and Assessment | |||||||
| TR-12.1 | Evaluation and Assessment - Learner Competency Assessments The Supplier shall carry out learner competency assessments to determine whether users are able to use the required system or Capability correctly. The Supplier will:
| MUST | No | Full Assessment Supporting evidence to include:
Ongoing compliance:
| Self-certification with Supporting Evidence Supporting evidence to include:
Ongoing compliance:
| Self-certification with Supporting Evidence Supporting evidence to include:
Ongoing compliance:
|
| TR-12.3 | Evaluation and Assessment - Authority Sample Surveys The Supplier will take action to remedy any issues identified from sample surveys on End User competency and satisfaction carried out by The Authority. | MUST | Yes | Self-certification | Self-certification | Self-certification |
| TR-12.4 | Evaluation and Assessment - Additional training and support The Supplier shall provide additional training and/or support where issues are identified through the evaluation and assessment process. For example, where negative feedback has been received, Go-Live has been delayed or the learners don't reach the required level of competency. | MUST | Yes | Self-certification | Self-certification | Self-certification |
Roadmap¶
Items on the Roadmap which impact or relate to this Standard
| Roadmap Item | Standards and Capabilities | Status | Effective Date | Description | Change Type | Change Route |
|---|---|---|---|---|---|---|
| Updates to external standards in Hosting and Infrastructure | Draft |
| Updating hyperlinks to external standards to the most recent version and removing references to specific editions | Uplift | Managed Capacity - Minor/Patch uplifts | |
| Changes to Information Governance requirements | Information Governance, Authentication and Access, Baseline Assurance Standard | Published |
| Additions, removals and amendments to requirements in the Information Governance Standard | Uplift | Managed Capacity - Other |
| Data Migration Standard - Mandating Out of Hours Cutover | Draft | TBC | Requirements uplifted to support the mandating of an out of hours cutover as part of the overall Data Migration process | Uplift | Managed Capacity - Other |